• Check whether the cable is broken before use.
• Check whether the electric pump is damaged in the course of transportation, the leakage, damage and death of the pump.
• The power supply is used in the control cabinet of the protection device.
• The personnel and animal husbandry must be kept more than 15 meters at the time of operation.
• Absolutely prohibit the same pool in the same water pool.
• If you have any questions in use, please contact our sales office in time or call our company's free service phone.
• 25 cm from the bottom of the pool.
• Avoid hard materials such as sucking stones, screw iron nails and so on; it can prolong the service life of the cutting device.
• After the replacement of the cutting device, special attention should be paid to the clearance between the impeller and the cutting disc, which should be controlled between 0.1-0.25mm.
• The use of the environment must be a liquid-based liquid.
• When the liquid has too little slag, it must be started after adding water.
Comparison of the advantages of spiral impeller cutting pump and traditional mode cutting pump
Model | WQAS | GNWQ | ZGWQ |
Image | |||
Structure | |||
Impeller |
Low-cutting effect through large particle head |
Spiral impeller |
Spiral alloy impeller |
Cutter's hardness | 32HR | 48HR |
58HR-65HR |
Pump body | HT250 | HT250 | HT250 |
Screw & handle | Steel | Steel | SUS304 stainless steel |
Protector | None |
Not have |
Disc-type thermal protector |
Mechanical seal |
Graphite-Ceramics | Sic-Graphite | Sic-Sic/Carbon-Sic |
Bearing |
Made in China |
Made in China |
C&U/ NSK |
Test: capacity/head/power | 24.72m3/h 12.8m 3kW | 35m3/h 12 .8m 2.2kW | 35m3/h 13 .8m 2.2kW |
Model | Caliber (inch) | Flow(m3/h) | Head(m) | Power(kW) | Speed(r/min) | Current source |
40ZGWQD6-12-0.75 | 1.5 | 6 | 12 | 0.75 | 3000 | 220V |
50ZGWQD10-10-0.75 | 2 | 10 | 10 | 0.75 | 3000 | 220V |
40ZGWQD7-15-1.1 | 1.5 | 7 | 15 | 1.1 | 3000 | 220V |
50ZGWQD12-10-1.1 | 2 | 12 | 10 | 1.1 | 3000 | 220V |
50ZGWQD15-15-1.5 | 2 | 15 | 15 | 1.5 | 3000 | 220V |
65ZGWQD25-10-1.5 | 2.5 | 25 | 10 | 1.5 | 3000 | 220V |
40ZGWQ6-12-0.75 | 1.5 | 6 | 12 | 0.75 | 3000 | 380V |
50ZGWQ10-10-0.75 | 2 | 10 | 10 | 0.75 | 3000 | 380V |
40ZGWQ7-15-1.1 | 1.5 | 7 | 15 | 1.1 | 3000 | 380V |
50ZGWQ12-10-1.1 | 2 | 12 | 10 | 1.1 | 3000 | 380V |
50ZGWQ15-15-1.5 | 2 | 15 | 15 | 1.5 | 3000 | 380V |
65ZGWQ25-10-1.5 | 2.5 | 25 | 10 | 1.5 | 3000 | 380V |
50ZGWQ9-22-2.2 | 2 | 9 | 22 | 2.2 | 3000 | 380V |
65ZGWQ20-18-2.2 | 2.5 | 20 | 18 | 2.2 | 3000 | 380V |
80ZGWQ45-9-2.2 | 3 | 45 | 9 | 2.2 | 3000 | 380V |
50ZGWQ15-22-3 | 2 | 15 | 22 | 3 | 3000 | 380V |
65ZGWQ35-15-3 | 2.5 | 35 | 15 | 3 | 3000 | 380V |
80ZGWQ43-13-3 | 3 | 43 | 13 | 3 | 3000 | 380V |
100ZGWQ60-9-3 | 4 | 60 | 9 | 3 | 3000 | 380V |
50ZGWQ15-25-4 | 2 | 15 | 25 | 4 | 3000 | 380V |
65ZGWQ26-22-4 | 2.5 | 26 | 22 | 4 | 3000 | 380V |
80ZGWQ45-17-4 | 3 | 45 | 17 | 4 | 3000 | 380V |
100ZGWQ65-12-4 | 4 | 65 | 12 | 4 | 3000 | 380V |
50ZGWQ15-40-5.5 | 2 | 15 | 40 | 5.5 | 3000 | 380V |
65ZGWQ25-30-5.5 | 2.5 | 25 | 30 | 5.5 | 3000 | 380V |
80ZGWQ45-20-5.5 | 3 | 45 | 20 | 5.5 | 3000 | 380V |
100ZGWQ65-16-5.5 | 4 | 65 | 16 | 5.5 | 3000 | 380V |
50ZGWQ15-45-7.5 | 2 | 15 | 45 | 7.5 | 3000 | 380V |
65ZGWQ25-35-7.5 | 2.5 | 25 | 35 | 7.5 | 3000 | 380V |
80ZGWQ45-25-75 | 3 | 45 | 25 | 7.5 | 3000 | 380V |
100ZGWQ60-22-7.5 | 4 | 60 | 22 | 7.5 | 3000 | 380V |
100ZGWQ100-15-7.5 | 4 | 100 | 15 | 7.5 | 3000 | 380V |
Model | Caliber (inch) | Flow(m3/h) | Head(m) | Power(kW) | Speed(r/min) | Current source |
40ZGWQD6-12-0.75 | 1.5 | 6 | 12 | 0.75 | 3000 | 220V |
50ZGWQD10-10-0.75 | 2 | 10 | 10 | 0.75 | 3000 | 220V |
40ZGWQD7-15-1.1 | 1.5 | 7 | 5 | 1.1 | 3000 | 220V |
50ZGWQD12-10-1.1 | 2 | 12 | 0 | 1.1 | 3000 | 220V |
50ZGWQD15-15-1.5 | 2 | 15 | 15 | 1.5 | 3000 | 220V |
65ZGWQD25-10-1.5 | 2.5 | 25 | 0 | 1.5 | 3000 | 220V |
40ZGWQ6-12-0.75 | 1.5 | 6 | 12 | 0.75 | 3000 | 380V |
50ZGWQ10-10-0.75 | 2 | 10 | 10 | 0.75 | 3000 | 380V |
40ZGWQ7-15-1.1 | 1.5 | 7 | 15 | 1.1 | 3000 | 380V |
50ZGWQ12-10-1.1 | 2 | 12 | 10 | 1.1 | 3000 | 380V |
50ZGWQ15-15-1.5 | 2 | 15 | 5 | 1.5 | 3000 | 380V |
65ZGWQ25-10-1.5. | 2.5 | 25 | 10 | 1.5 | 3000 | 380V |
50ZGWQ9-22-2.2 | 2 | 9 | 22 | 2.2 | 3000 | 380V |
65ZGWQ20-18-2.2 | 2.5 | 20 | 18 | 2.2 | 3000 | 380V |
80ZGWQ45-9-2.2 | 3 | 45 | 9 | 2.2 | 3000 | 380V |
50ZGWQ15-22-3 | 2 | 15 | 22 | 3 | 3000 | 380V |
65ZGWQ35-15-3 | 2.5 | 35 | 5 | 3 | 3000 | 380V |
80ZGWQ43-13-3 | 3 | 43 | 13 | 3 | 3000 | 380V |
100ZGWQ60-9-3 | 4 | 60 | 9 | 3 | 3000 | 380V |
50ZGWQ15-25-4 | 2 | 15 | 25 | 4 | 3000 | 380V |
65ZGWQ26-22-4 | 2.5 | 26 | 22 | 4 | 3000 | 380V |
80ZGWQ45-17-4 | 3 | 45 | 17 | 4 | 3000 | 380V |
100ZGWQ65-12-4 | 4 | 65 | 12 | 4 | 3000 | 380V |
We are a custom ZGWQ Cutting Sewage Pump and ZGWQ Cutting Sewage Pump exporter enterprise integrating development, production, and marketing. Founded in 1995, since its establishment, it has only focused on one thing - pump manufacturing. The geographical location is Dayangcheng Industrial Zone, Daxi Town, Wenling City, Zhejiang Province, China. We have been adhering to the business philosophy of "people-oriented, winning the market with quality", and wholeheartedly provide customers with high-tech, high-quality, humanized products and services.
View MoreWe are a professional water pump enterprise integrating development, production, and sales. Keep up to date with our latest industry trends and company updates by reading the news.
Basement flooding is a common problem, especially during heavy rain or spring thaws. For homeowners and property managers, having a reliable solution is essential to prevent water damage and costly repairs. Submersible dewatering ...
Read More +Deep beneath the surface, submersible drainage pumps and dewatering sewage pumps embark on vital underground “adventures,” working tirelessly to manage water and sewage in challenging conditions. In a world, these pumps navigate d...
Read More +Selecting the proper equipment for water management is critical in construction and industrial projects. Whether it's managing mud or handling large-scale water needs, choosing between a dewatering mud pump and a large submersible...
Read More +In various industries, from construction to mining, efficient water removal is critical. Dewatering Pumps play a vital role in managing water levels, preventing equipment damage, and maintaining safe and productive work environmen...
Read More +In factory wastewater management, industrial sewage grinder pumps play a crucial role. These pumps are specifically designed to handle the solid-laden effluents produced by various industrial processes, from food processing to che...
Read More +